Lab Equipment Expert

Message us

Ask Our Expertise

Generate Catalog For:
Atomic Absorption Spectrophotometer TRAS-701
Atomic Absorption Spectrophotometer TRAS-701

Atomic Absorption Spectrophotometer TRAS-701

www.Iranscientific.com | info@Iranscientific.net

Overview

Atomic Absorption Spectrophotometer TRAS-701is completely controlled by a computer. It has a fully automatic control system with advanced temperature control technology of a graphite furnace. With a wavelength range of 190 to 900 nm. Providing a spectral bandwidth of 0.1, 0.2, 0.4, 1.0, and 2.0 nm. The setting of the background deduction method. The fast heating capacity can improve the elements' flexibility even more. . It presents the hollow cathode lamp in its operational state. It is a safe, dependable, and convenient flame system with a multi-functional software workstation.

Specifications :
Wavelength range  190 to 900 nm
Spectral bandwidth 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Accuracy of the wavelength ±0.15 nm
Receptivity of the wavelength  ≤0.04 nm
Baseline stability ≤0.002A/30 min (Cu)
Characteristic viscosity 0.02 μg/ml/1% (Cu)
Checking limit 0.004 μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/ mm
Inflamer All-metal titanium burner
Atomizer  Effective glass atomizer
Lamp stand 8
D2 background correction ability When the background is 1 A, the background ability should be deducted not less than 50 times, self-absorption background deduction method
Size  700 mm×550 mm×450 mm  
weight 75 Kg
Power source 220V±22V AC
Flame System
Acetylene air burner 100 mm
Ignition dynamic baseline drift ≤0.006 A/30 min
(Cu) Characteristic viscosity ≤0.025 μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008 μg/ml)
Safety system Can Automatically cut off the gas when The pressure is not enough, The power is off, flameout and unconformity of the burner.
Graphite furnace
The highest temperature 3000 ℃
The largest temperature rising speed ≥2000 ℃/S
Characteristic quantity Cd≤0.5×10 to12 g
 Cu≤0.5×10 to 11 g
Accuracy Cu≤3% Cd≤3 %
Size and weight 550 mm×450 mm×300 mm  65 Kg
Power source and power 220 V±22 V  AC  7000 W
Features :
  • -  The hollow cathode lamp's operational state
  • -  Wavelength searching and peak search are completely automatic
  • -  The integrated floated optical platform design improves the optical system's shock resistance and stability when using the optical signal for an extended period
  • -  Eight light stands can be changed automatically while simultaneously preheating and optimizing the eight lights
  • -  Adjustable position: It can automatically set the front and rear positions, as well as the best height for the flame burner
  • -  The setting of the background deduction method
  • -  Background self-absorption and the Deuterium lamp
  • -  Data processing, super-strong database with over 500 data self-storage and cut-off storage functions
  • -  can hold the analysis results in form of a Spreadsheet, and the test procedure and result can be called at random
  • -  The flame results demonstrated and the emissions technique are two methods for measuring
  • -  Result printing: parameter printing, data result printing, and diagram printing
  • -  It has fully automatic controlled, with the help of the software
  • -  The selection of lamp elements, Front-to-rear lifter adjustment (up/down)
  • -  Re-adjustment of optical energy, selecting the slit, Determination of wavelength scanning and peak searching, sixth, choosing an atomizer
  • -  Full safety chain protection, warning and automatic protection against incorrect burner, gas leakage, air under voltage, and abnormal flameout
  • -  Managing the flow of gas
  • -  Auto-flaming and extinguishing
  • -  Temperature control technology of graphite furnace advanced
  • -  Introducing PID technology can effectively overcome the influence on the temperature rising procedure
  • -  The combination of the 3ms/time fast sampling technique can result in more accurate and dependable testing data
  • -  The fast heating capacity can improve the elements' flexibility even more
  • -  Use a standard 220V power source instead of a 380V dynamic power source
  • -  The maximum procedure heating capacity setting of 20 levels can make testing multiple samples more efficient and comfortable
  • -  Three grades of adjustable gas flow can be tailored to meet a variety of application requirements
  • -  Can provide a timely warning when the gas and water are turned off and there is insufficient gas and water, thereby avoiding equipment damage and measurement error
  • -  Safe, reliable, and convenient flame system
  • -  EPC can more precisely control the flow of acetylene (C2H2) and is a type of system that is also simple to operate
  • -  A well-functioning Tomi Ziti on the system allows for greater sensitivity
  • -  The entire operating system is highly secure because the fire safety system scan alert for the fluctuation
  • -  It will also automatically turn off the gas and prohibit temper tantrums
  • -  Protects the operating personnel and equipment from harm and damage
  • -  Multi-functional software workstation, a working computer that is supported WINDOWS XP/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000/NT/2000
  • -  The extensive menu makes it easy for customers to use
  • -  Easy conversion between different menus simplifies the operation
  • -  A variety of analytical correction methods gives users more options
  • -  The basic default parameter settings allow even inexperienced users to perform routine operations
  • -  Flexible storage, editing, and printing methods provide the most support to the user